ISO 6507-1 PDF

hardness test —. Part 1: Test method. Matériaux métalliques — Essai de dureté Vickers —. Partie 1: Méthode d’essai. STANDARD. ISO. Fourth edition. ISO INTERNATIONAL. STANDARD. ISO. Third edition. Metallic materials — Vickers hardness test —. Part 1: Test method. Matériaux . I.S. EN ISO is the adopted Irish version of the European . The text of ISO has been approved by CEN as EN ISO.

Author: Mazucage Zulutilar
Country: Belgium
Language: English (Spanish)
Genre: Medical
Published (Last): 1 August 2012
Pages: 430
PDF File Size: 5.97 Mb
ePub File Size: 11.52 Mb
ISBN: 632-7-95335-747-6
Downloads: 61050
Price: Free* [*Free Regsitration Required]
Uploader: Mikazahn

The corresponding effect on the termination of the formation of an indentation can make alterations in the hardness value. If 650-71 difference is greater, this shall be stated in the test report.

Standards Subsctiption may 65077-1 the perfect solution. NOTE There is evidence that some materials may be sensitive to the rate of straining which causes small changes in the value of the yield strength. The work of preparing International Standards is normally carried out through ISO technical 6507–1. In GUM, it is recommended to use a correction to compensate for such systematic effects.

This standard is not included in any packages. If two adjacent indentations differ in size, the spacing shall be based on the mean diagonal length of the larger indentation.

HV 2,5 24,52 N may be used. Ido Subscriptions from ANSI provides a money-saving, multi-user solution for accessing standards. Adobe is a trademark of Adobe Systems Incorporated. In accordance with Adobe’s licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing.

TOP Related Posts  EMINENCE ALPHALITE 6A PDF

BS EN ISO 6507-1:2018

6570-1 The correction factors are tabulated in terms of 65507-1 ratio of the mean diagonal d of the indentation to the diameter D of the cylinder. In this case, an estimate of type A standard uncertainty may be obtained from the statistical analysis of repeated indentations into the test piece. Reference number ISO Ihre Klassifizierung und Auswirkung auf die Messwerte. The duration of the test force shall be 10 s to 15 s, except for tests on materials whose time-dependent properties would make this an unsuitable range.

Please first log in with a verified email before subscribing to alerts. M2 may lead to smaller values of uncertainty. The time from the initial application of the force 65071- the full test force is reached shall not be less than 2 s nor greater than 8 s.

Your Alert Profile lists the documents that will be monitored.

BS EN ISO – Metallic materials. Vickers hardness test. Test method

Care should be taken, if standard uncertainties of type A and B are summarised, that the contributions are not counted twice see Clause 4 of GUM: If the measuring system fails this test, appropriate action should be taken. Figure 1 — Principle of the test The Vickers hardness is proportional to the quotient obtained by dividing the test force by the sloping area of the indentation, which is assumed to be a right pyramid with a square base, and having at the vertex the same angle as the indenter.

TOP Related Posts  DISANO RIGO PDF

This jso the base of M2.

No deformation shall be visible at the back of the test piece after the test. VDI-Berichte 11pp. The distance between the centres of two adjacent indentations shall be at least three times the mean diagonal length of the indentation in the case of steel, copper and copper alloys, and at least six times the mean diagonal length in the case of light metals, lead and tin and their alloys.

Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. A record of these results should be maintained over a period of time, and used to measure reproducibility and monitor drift of the machine.

The procedure for the determination of U is explained in Table D. Due to the isp depth of Vickers microhardness indentations, it is essential that special precautions are taken during preparation.

The Vickers hardness test is specified in this part of ISO for lengths of indentation diagonals between 0, mm and 1, mm. NOTE 1 For indentation diagonals less than 0, mm, the increase of the uncertainty has to be considered.

ISO : 金属维氏硬度试验 第一部分:试验方法 – MBA智库文档

We have no amendments or corrections for this standard. Please first verify your email before subscribing to alerts. Naturally, direct calibration and the verification of these machines should be at the highest possible accuracy.

TOP Related Posts  DCIG 2013 VIRTUAL SERVER BACKUP SOFTWARE PDF

For dated references, only the edition cited applies. In M1, the error limit, that means the range in which the machine is allowed to differ from the reference standard is used to define the source uE of the uncertainty. There is no general process of accurately converting Vickers hardness into other scales of hardness or into tensile strength.

Test method 1 Scope This part of ISO specifies the Vickers hardness test method, for the three different ranges of test force for metallic materials see Table 1.

If not, an indirect verification should be performed.

As the voice of the U. The support surfaces shall be clean and free from foreign matter scale, oil, dirt, etc.

The check involves at least one indentation being made on a hardness reference block, calibrated in accordance with ISO The specification for the product may indicate limits for the differences between 6057-1 lengths of the two diagonals. You may delete a document from your Alert Profile at any time.

The required thickness is given by the 65071- of intersection of the minimum thickness scale and a line shown dotted in the example in Figure A.

Independent of the type of sources, for hardness there are two possibilities for the determination of the uncertainty.